Electrical connection, Caution, Connection of the hob – ilve HVI90TC User Manual

Page 25

Advertising
background image

25

ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be

entrusted only to an electrician perfectly to the fact of the normative regulations and
which respects them scrupulously.

Protection against the parts under tension must be ensured after the builting-in.

The data of connection necessary are on the stickers place on the hob casing near the

connection box.

The connection to the main must be made using an earthed plug or via an omnipolar

circuit breaking device with a contact opening of at least 3 mm.

The electrical circuit must be separated from the network by adapted devices, for

example : circuit breakers, fuses or contactors.

Mains

Connection

Cable diameter

Cable

Protection calibre

230V~1P+N 50Hz

1 Phases + N

3 x 4 mm²

H 05 RR

40 A *

400V~2P+N 50Hz

2 Phases + N

4 x 2.5 mm²

H 05 RR

25 A *

400V~3P+N 50Hz

3 Phases + N

5 x 1.5 mm²

H 05 RR

16 A *

( * ) calculated with the simultaneous factor following standard TN 60 335-2-6/1990

Caution !

Connect always the earth wire .
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver. Place it in the slits and open the cover.

Connection of the hob

Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the
terminal
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2, 2 and 3 then a bridge between 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 5 (or 4), the Phase L to one
of the terminals 1 2, or 3.
Biphase 400V~2P+N
Put the 1

st

bridge between terminal 1 and 2, the 2

nd

between 4 and 5.

Attach the earth to the terminate “earth”, the neutral N to terminal 5 (or 4), the Phase L1 to the
terminals 2 and the Phase L2 to the terminal 3.
Triphase 400V~3P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate “earth”, the neutral N to terminal 5 (or 4), the Phase L1 to the
terminals 1, the Phase L2 to the terminal 2 and the Phase L3 to the terminal 3.

We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.