4.

MaintenanCe

NOTE!

Be careful when handling electrical cables!

In maintaining the unit, take into consideration the rate of use and the

environment it is used in. When the unit is used properly and serviced

regularly, you will avoid unnecessary disturbances in use and production.

4.1

daily MaintenanCe

Perform the following maintenance daily:

• Clean electrode holder and TIG torch’s gas nozzle. Replace damaged or

worn parts.

• Check TIG torch’s electrode. Replace or sharpen, if necessary.

• Check tightness of welding and earth cables connections.

• Check condition of mains and welding cables and replace damaged

cables.

• See that there is enough space in front of and back of the unit for

ventilation.

4.2

trOuBleshOOting

Problem

Cause

The main switch indicator will not

light up

No electricity connected to the machine

• Check the mains supply fuses.

• Check the mains cable and plug.

Poor welding result

Several factors affect the welding quality.

• Check that the earthing clamp is firmly attached, the point of

attachment is clean and that the cable and its connectors are

intact.

• Check that the shielding gas flows out of the torch tip.

• Check that the electric voltage is not irregular or too low/high.

Overheating indicator lit

The device has overheated.

• Ensure that cooling air has unrestricted flow.

• If the machine’s duty cycle has been exceeded, wait for indicator to

turn off.

• Too low or high supply voltage.

If the machine’s malfunction is not eliminated with these measures, contact

KEMPPI service.