Connecting the cooktop to the mains power supply, Warning, Connection – Kleenmaid CH605SX User Manual

Page 8: Colour code

Advertising
background image

Instructions for Use, Building- in and Connecting

8

Connecting the cooktop to the mains power
supply

Warning

Electric connection must be carried out by
qualified service personnel only!

Before connection, check whether the voltage
indicated on the rating plate corresponds to the
actual mains voltage.

Mains lead should be minimum 1.5 m long, so
that the cooktop may be removed for servicing.

Mains voltage of the user (240 V) must be
verified with the measuring device!

Three separating switches should be placed in
accordance with the mains connection.

Earthing wire should be installed in such
manner to be the last one pulled out in case the
safety relief device of the mains lead should fail.

Connection

Electrical connection must be carried out by
qualified service personnel only!
Wrong connection may permanently damage
parts of the appliance and render your
warranty void!
Prior to connection make sure the voltage from
the rating plate agrees with the existing mains
voltage supply. Mains voltage of the user (240 V)
must be verified with the measuring device!

Open the connector at the bottom of the
cooktop by means of screwdriver and slightly
push it downwards. Release the brackets
located left and right of the connector.

Mains lead must pass through the relief safety
device, protecting the mains lead cable from
disconnection.

Connect the appliance according to one of the
illustrated possibilities.

Tighten the relief device securely and close the
connector cover.

Colour code

L1, L2 = exterior live wires, usually coloured
black, black, brown.

N = neutral
The colour is usually blue.
Beware of the correct N-connection!

PE = earthing wire
The colour is green/yellow.

WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS WITH NO INFLUENCE ON
THE OPERATION OF THE APPLIANCE.

Advertising