Mod. 2G

Adaptation to varius types of gas (Fig. 10)

Should the appliance be pre-set for a different type of

gas than available, procreed as follows:

• replace the injector (Fig. 7) with the corresponding type

of gas to be used (see table “User characteristics“);

A

B

Mod. Dual

Fig. 10

Minimum burner capacity regulation procedure
The procedure for acquiring the minimum capacities

allows the operator to change the minimum capacity

programmed, adapting every burner to the characteristics

of the gas distribution network to which the hob is

connected.

The procedure is activated by pressing the +A and –A

keys together with the +B key constantly for 3 seconds,

with the burners all switched off.

The activation of the regulation procedure is indicated

on the display with the word "MIN". It is now possible to

select the burner to regulate using the respective + and –

keys. After pressing one of the keys, the burner selected

will come on at minimum level and it will be possible to

increase or reduce the capacity to the minimum level

using the

+

and

keys

for

this

burner.

During the

display

regulation procedure, the flame display levels

will show the indication - if the minimum level programmed

corresponds with the factory setting, and the indication will

change ^ or v in flashing mode, indicating a higher or lower

capacity than that programmed. The procedure ends by

pressing the PT key. The minimum capacity levels will

then be acquired and memorised by the device, and will

be used in the normal use of the hob.

Selecting the type of fuel gas
You can configure the cook top to work with different

gases (see table 1). To select the fuel gas to use, the

cook top must be on with all the burners off. Just press

the burner A, burner B and P- keys together for at least 2

seconds. When the fuel gas selection procedure starts,

the burner level display turns off and the timer display

shows “2020”, “3029”, “2525” or “2010”, depending on

the current configuration in use. It is possible to select

the desired setting with the A+ and A- keys. To end the

procedure, you must press the PT key.

Using this function deletes any turn-off times that may

have been programmed for the burners.

Electronic self-test
The electronic cards are continuously checking their

status. If there are any hardware or board problems that

could affect the end-user's safety, the cook top goes

into a “safe” mode which closes the solenoid valves and

displays a code relative to failure.