Für den Benutzer

F

O

R

T

H

E

I

N

S

T

A

L

L

E

R

As a specialist, you are the only person qualified to carry out the installation and connection of cooking appliances.
For this reason, our guarantee applies solely and exclusively to appliances for which you have carried out the installation and
connection in accordance with current regulations.

Non-compliance with this condition will be the installer's responsibility and Kleenmaid will not be liable in any way.

Building-in the oven ( fig. 1)

The oven has an optimised air circulation system which enables the achievement of excellent cooking
results and easy cleaning.

The total control of this air circulation system means that you should take note of the following:

The oven may be installed with equal success under a worktop or in a column unit, as the hot air outlet is at the
front.

The fitting dimensions must be appropriate (see fig. 1).

The material used for the housing unit must be heat resistant (or be covered with such a material).

The distance between the oven and the sides of the unit, to the left and the right, must be the same so that it is
correctly centred in relation to the doors of the neighbouring unit; this distance must be at least 2 mm.

For greater stability, fix the oven into the unit using 2 screws in the holes provided in the lateral uprights (see fig.1).

Drill a 3 mm hole beforehand in the wall of the unit to prevent the wood splitting.

Technical data

Operating voltage ........................... 240 V

~

50 Hz

Total electrical power consumption ........ 3.065 kW
Power rating of grill ...................................2.635 kW

Energy consumption

- heating to 200 °C ................................. 0.55 kWh
- running for one hour at 200 °C ............ 0.87 kWh
TOTAL .................................................... 1.42 kWh

Usable dimensions of oven
Width ............................................................ 43 cm
Height ........................................................ 31.5 cm
Depth ............................................................ 40 cm

Usable volume .......................................... 54 litres

Connecting the oven

(Fig. 2)

Before carrying out the connection, make sure that the cable from your mains supply have a sufficient rating to
supply the appliance correctly.

Electrical connection must be carried out before the appliance is fitted into the unit.

The appliance must be connected to the power supply of 240V single phase, 20 AMP-circuit minimun.
The earth wire (yellow/green) must be connected to the earth terminal on the appliance.

Kleenmaid will not be liable in the event of an accident resulting from non-existent, faulty or incorrect earthing.

The neutral supply must be connected to the neutral terminal on the terminal block.

To gain access to the terminal block :

Using a pair of pliers, cut the fixings on the four corners of the access flap on the rear panel of the oven.

Replace the access flap in such a way that the opening is completely covered, using two metal screws with a
diameter of 4 mm and length of 15 mm.