Kleenmaid RHWMDB40 User Manual

Page 6

Advertising
background image

6

We recommend that you wear gloves during installation and maintenance.
When installing an extracting version (the extracted air is sent outside = Fig. A), it is important to:

- prepare an air exhaust hole and duct with a diameter of 150 mm.

- use a duct that is as short as possible

- use a duct with the least number of curves possible (maximum curve angle 90°)

- avoid the use of flat ducts and ducts of different section as much as possible

- use a duct with the smoothest possible interior and conforming to the standard

- do not connect the hood to a duct that exhausts fumes produced by combustion (fireplaces, boilers, ovens, etc.)

- do not discharge the air into a cavity in the wall unless the cavity has been prepared for that purpose.

- provide the room with air intakes so that the hood does not create negative suction (no higher than 0.04 mbar).

When installing a filtering version (the extracted air is returned to the kitchen = Fig. B) there is no need to prepare a

hole and exhaust duct, but you must provide two activated carbon filters (request them separately as an accessory).

Fig. 1: using the fixing bracket (1), mark the positions of the fastening holes on the ceiling.

Fasten using no. 2 anchors Ø 8 + no. 2 screws Ø 4.8x38 + no. 2 washers.

Fig. 2: attach the cover with grill (2) to the fixing bracket (1). (If you wish this cover can be omitted in the extracting

version).