6-1 COMPRESSOR AND ELECTRIC COMPONENTS

6. TROUBLESHOOTING

- 10 -

1-
-

2-

3-

4-

5-

2-

5-

5-

3-

5-

4-

5-

5-

1-
-

4-

3-

YES-

YES-

YES-

YES-

NO-

NO-

YES-

YES-

YES-

NO-

NO-

NO-

Power Source.

No Voltage.

(Rating Voltage
±10%)?

Replace OLP.

Reconnect.

Replace
PTC-Starter.

Replace OLP.

O.K.

Check connection
condition.

OLP disconnected?

Advise the customer
to use a regular
TRANS.

Replace Compressor.

OLP works within
30 sec. in forcible OLP
operation by turning
instant power on and
off.

Components start in
the voltage of Rating
Voltage ±10%
below.

Applied voltage isn't
in the range of Rating
Voltage ±10%.

Remove the PTC-
Starter from the
Compressor and
measure the voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.

Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.

Check the resistance
of two terminals in
PTC-Starter.

Check if applying
a regular OLP.

Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.

Check the
resistance of
Motor
Compressor.

Check the
resistance of
PTC-Starter.

Check OLP.

Check
starting state.