© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

19

506066

NOTE: When connecting gas supply line, a
pressure test point must be installed downstream
from the shut-off valve for checking inlet gas
pressure.

5. The gas line to your laundry room should be

made of black iron pipe. A 9.5 mm (3/8 inch)

pipe with an inside diameter of 11.7 mm

(0.46 inch) will be adequate if length of supply

line is not over 6 m (20 feet). If length exceeds

this, use 12.7 mm (1/2 inch) pipe. If copper semi-

rigid tubing is used, it must be internally tinned

or equivalently treated to resist sulfur corrosion.

NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 3.45 kPa (1/2 psig).

6. Check all pipe connections (internal and

external) for gas leaks with a soapy solution. Gas

connections should be checked annually for

leakage.

7. Be sure the shut-off valve in your dryer is OPEN.

Your dryer is shipped with the valve open.

8. The dryer gas valve is equipped with a pressure

test point for checking manifold pressure.

For proper operation at altitudes above 760 m

(2500 feet), the natural gas valve spud orifice size

must be reduced to ensure complete combustion. Refer

to Table 1 and Table 2.

Natural Gas Altitude Adjustments

Altitude

Orifice Size

Part No.

m

feet

No.

mm

inche

s

760

2500

45

2.08

0.0820

503779

1370

4500

46

2.06

0.0810

503780

1830

6000

47

1.99

0.0785

503781

2290

7500

48

1.93

0.0760

503782

2900

9500

49

1.85

0.0730

503783

3355

11,00

0

50

1.78

0.0700

503784

Table 1

L.P. Altitude Adjustments

Altitude

Orifice Size

Part No.

m

feet

No.

mm

inche

s

1370

4500

56

1.2

0.0465

503786

3000

9500

57

1.1

0.043

60941

Table 2