144 mhz band, Rx tune adjustment, Squelch threshold adjustment – Yaesu VX-3R Сервис-мануал User Manual

Page 13: Squelch tight adjustment, Nfm s-meter s-1 adjustment, Nfm s-meter full scale adjustment, Wfm s-meter s-1 adjustment, Wfm s-meter full scale adjustment, High tx power adjustment, Alignment

Advertising
background image

13

Alignment

144 MHz Band

Press the [BAND] button to switch the alignment band to

144 MHz Band.
RX Tune Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to -10 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).

P

Connect the SINAD meter to the MIC/SP jack

P

Rotate the DIAL knob clockwise until the alignment

item "tUn" appears.

P

Press the [V/M] key.

P

Rotate the DIAL knob for minimum defection of the

SINAD meter.

P

Press the [V/M] key again.

Squelch Threshold Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to -12 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).

P

Rotate the DIAL knob counter-clockwise until the align-

ment item "tHL" appears

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

Squelch Tight Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to -5 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).

P

Rotate the DIAL knob one click clockwise to select the

alignment item "tIg".

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

NFM S-Meter S-1 Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to -7 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).

P

Rotate the DIAL knob one click clockwise to select the

alignment item "S1".

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

NFM S-Meter Full Scale Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to +20 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).

P

Rotate the DIAL knob one click clockwise to select the

alignment item "S9".

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

WFM S-Meter S-1 Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to 0 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±20 kHz deviation).

P

Rotate the DIAL knob one click clockwise to select the

alignment item "S1".

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

WFM S-Meter Full Scale Adjustment

P

Connect the RF Signal Generator to the ANT jack, and

then set the output level to +20 dBμV at the 145.100 MHz
(with 1 kHz tone @ ±20 kHz deviation).

P

Rotate the DIAL knob one click clockwise to select the

alignment item "S9".

P

Press the [V/M] key.

P

Press the [F/W] key twice, and then press the [V/M] key

again.

High TX Power Adjustment

P

Connect the 50-Ohm Dummy Load and Wattmeter to

the ANT jack.

P

Increase the DC power supply voltage to 6.0 V

P

Rotate the DIAL knob one click clockwise to select the

alignment item "HHP".

P

Press the [V/M] key.

P

Press the PTT switch, then rotate the DIAL knob so that

the Wattmeter reading is 2.9 W ±0.1 W.

P

Reduce the DC power supply voltage to 4.4 V

P

Rotate the DIAL knob one click clockwise to select the

alignment item "HP".

P

Press the [V/M] key.

P

Press the PTT switch, then rotate the DIAL knob so that

the Wattmeter reading is 1.5 W ±0.1 W.

P

Press the [V/M] key again.