INSTALLATION INSTRUCTIONS

I. VEHICLE TUBING OF THE AUTO PUMP 12V

1. Mount all components in a suitable location, preferably in a high area above the air system. Do not

mount in engine compartment or near any source of heat or dirt . The system may be connected
to any point in the vehicle’s air system.

2. Mount the air compressor in a vertical position as shown.

3. CAUTION: No condensate or water must be allowed to enter or accumulate in the output of the

Auto Pump. Route output pressure line downward from Auto Pump to permit moisture to drain
away.

Water in the pump outlet will induce failure and Void the Warranty.

4. All connection for air lines are 1/4” NPT. Use Teflon tape, or equivalent on all connections to in-

sure no leakage of air.

5. The recommended installation of the Auto Pump air compressor system is shown below.
6. Mount the air compressor. Connect a suitable piece of flexible tubing from the outlet port of com-

pressor to the air tank. (Tubing and connectors are not supplied).

7. An optional Mounting Plate 091-9H-12V-HP-H, is available to reduce any vibration and noise from

Auto Pump and to simplify pump mounting.

II. VEHICLE TUBING DIAGRAM

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826