KUSSMAUL ELECTRONICS COMPANY, INC.

170 CHERRY AVENUE, WEST SAYVILLE, NEW YORK, 11796-1221 USA

SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS

TEL. In NY:

TOLL FREE:

FAX:

631 567-0314

800 346-0857

631 567-5826

INSTALLATION INSTRUCTIONS

Model 091-167-12 Load Manager 1HP

The 091-167-12, Load Manager 1HP is a small waterproof assembly that monitors a D.C. volt-

age and operates a relay when the voltage drops below its set point.

With the engine running and battery voltage above 12.8 volts, the relay is energized and power is

supplied to the loads.

With the engine stopped and continuous loads that reduce the battery below +11.5 volts, the

relay will drop out and prevent complete discharge of the battery. The relay remains de-ener-

gized until the battery voltage returns to +12.8 volts or higher.

An optional starter input prevents the relay from dropping out during the cranking cycle if the

voltage prior to cranking was sufficient (+11.5 volts).

Note: the starter input is not required for normal operation if cranking shutdown protection is not

required.

May 24, 2007

4 3 2 1

Radio &

Computer

Loads

From
+12V

Battery

Size Fuse

for 25% Higher

Than Actual

Load

Fuse

+12V

From

Starter

(optional)

75 Amp

Relay

Input:

Relay Contact Rating:

12.8 +/- 0.1 Volts

11.5 +/- 0.1 Volts

75 Amperes D.C.

Specifications:

+12 Volts Nominal

Relay Pull-In:
Relay Drop-Out:

Advertising