ALTITUDE SETTING

After inserting batteries or adapter, the main unit will enter altitude setting mode directly.

Press “▲” or “▼” to select pressure unit in hPa, mb or inHg. Press “PRESSURE” to confirm.

Then press “▲” or “▼” to enter your current altitude in meter or feet. Press “PRESSURE”

to confirm and exit the setting. This allows the unit to provide a more accurate barometric

pressure & weather forecast reading. (For more information, see “WEATHER FORECAST &

BAROMETRIC PRESSURE” section)

SETTING UP THE WIRELESS THERMO-HYGROMETER:

• For the first installation, always turn on the home unit and then the remote sensor. Set

Channel 1 for the first remote sensor. Set channel 2 and channel 3 for the 2nd and 3rd

sensor.

• Press and hold CHANNEL button on main unit until a beep is sound to search for remote

sensor.

• Press the TX button on the back of remote sensor to transmit RF signal.

• When RF connection is established, the respective temperature & humidity of the selected

channel will appear on the main unit.

ATOMIC CLOCK

The unit will start synchronizing the clock after battery/adapter installation or reset. In normal

mode, press “ “ on the back of the display, to enforce searching of atomic clock signal. The

antenna icon will appear during synchronization, if the icon disappears afterwards, atomic

time signal is not available at the moment. Try other locations later. Place the unit away from

source of interference such as mobile phones, appliances, TV etc. Place the front or back of

the unit toward Colorado for best signal reception.

Antenna icon with full signal strength will appear on screen if the reception of atomic time

is successful. The atomic clock will have a daily synchronization at 02:03 and 03:03 everyday.

Each reception cycle is minimum 2.5 minutes and maximum 10 minutes.

WEATHER FORECAST & BAROMETRIC PRESSURE

The unit predicts weather condition of the next 12 – 24 hours based on the change of

atmospheric pressure. Allow 48-60 hours after set up for the unit to acclimate to your

environment. The coverage area is around 18.5 – 31 miles. The weather forecast is based

on atmospheric pressure change and is about 70-75% correct. As weather conditions cannot

be 100% correctly forecasted, we cannot be responsible for any loss caused by an incorrect

forecast.

SUNNY PARTLY CLOUDY CLOUDY

RAINY

STORMY

The current weather forecast is the one highlighted by a black-outlined square box.

To obtain an accurate weather forecast & barometric pressure reading, you need to input your

current altitude. After the reset of the unit, it will enter altitude setting mode. Press “▲” or “▼”

to set the pressure unit in hPa, mb or inHg. Press “PRESSURE” to confirm. Then enter your

current altitude in meter or feet. Press “PRESSURE” to confirm and exit the setting. You can

also hold “PRESSURE” button to enter altitude setting mode during normal use.

Press PRESSURE button to select pressure unit between hPa, inHg & mb.

W177.indd 3

9/15/07 10:21:37 AM

Advertising