1. WARNING: TEST THAT POWER IS OFF AT CIRCUIT BREAKER OR

FUSE BLOCK!

2. Determine approximate location (which joists to put it between) and

route cable(s) to joist cavity and fasten cable within 12" of proposed
opening per NEC 334.30 leaving large enough loop to later install box
after finishing floor installation.

3. Determine box location and

drill four 3/4" diameter holes
using

template

“A”

for

WMFB1 series or template
“B” for WMFB2 series.

Note: When installing tile,
marble or hardwood flooring,
you may want to wait to cut
the

opening

during

the

finished floor installation to
ensure the opening in the
floor does not end up in the
middle of a tile or hardwood
plank.

4. Cut remainder of opening

using the appropriate tem-
plate

by

connecting

the

edges of the holes.

5. Complete the finished floor

installation

up

to

the

previously

cut

opening,

ensuring the box will still fit
into opening.

6. Pull the wires through the

opening in floor and into the
auto-clamp feature. Knock-
outs are provided for low
voltage cables if desired. If
Romex-type

NM

cable

is

routed through the knockouts,
an approved wire clamp must
be used.

7. Attach box to flooring using

either the four #6 drywall
screws included or use the
assembled swing brackets.
Tighten screws firmly. When
assembling

to

carpet,

the

carpet

may

need

to

be

trimmed back to ensure the
box flange sets flush. Trim only
the carpet loops/shag and
leave the carpet backing under
the flange for security. Cut the
padding back 1-2" larger than
the opening to ensure the
device seats firmly and flush to
the floor.

8. Install device(s) per appropriate

installation instructions below.

WMFB-1 & WMFB-2 SERIES FLOOR BOX

INSTALLATION INSTRUCTIONS

NOTICE: READ BEFORE INSTALLING DEVICE

NEW/OLD CONSTRUCTION

FEATURES AND BENEFITS

3

2

4

7

6

Available Catalog #’s

Cat #

Description

WMFB1DR*

1 gang floor box, Duplex Cover, Duplex 15 amp Receptacle

WMFB1KS2*

1 gang floor box, Single Cover, Two Port Keystone Jack

WMFB1KS4*

1 gang floor box, Duplex Cover, Four Port Keystone Jack

WMFB1SR*

1 gang floor box, Single Cover, Single 15 amp Receptacle

WMFB1SRKS1*

1 gang floor box, Duplex Cover, Single 15 amp Receptacle &
1 Port Keystone Jack

WMFB2DR2*

2 gang floor box, Two Duplex Cover, Two Duplex 15 amp
Receptacles

WMFB2DRKS4* 2 gang floor box, Two Duplex Cover, Duplex 15 amp Receptacle

& 4 Port Keystone Jack

WMFB2KS8*

2 gang floor box, Two Duplex Cover, Two 4 Port Keystone Jack

*denotes: B = Brass Cover or N = Nickel Plated Cover

NOTICE: For installation only by a electrician or other
qualified person in accordance with the National Electrical
Code, Canadian Electrical Code, local Codes and the
instructions on this sheet.

CAUTION: RISK OF ELECTRICAL SHOCK. Turn off all power
to circuit before installing this device. Improper wiring of any
electrical device can cause serious injury or death.

CAUTION: Connect only copper or copper-clad wire to the
device in this package. Do not connect aluminum wire to this
device.

NOTE:

USE

ONLY

ELECTRICAL

MOUNTING

BOX

PROVIDED.

U.S. and International: 60 Woodlawn Street • West Hartford, CT 06110 • 1-800-621-0049 • FAX 860-232-2062 • Outside U.S.: 860-233-6251

P/N 340771 Rev. B

Canada: 570 Applewood Crescent • Vaughan, Ontario L4K 4B4 • 1-800-723-5175 • FAX 905-738-9721
www.wiremold.com

Printed in USA

-

-

-

-

Ø

Ø

• Exclusive Dual Voltage Single Gang Floor Box, great for TV’s,

Telephones and Laptop connections

• Complete line of low voltage connectors available through

Pass and Seymour (www.passandseymour.com).

• Installs before or after the floor is completed to ensure the best

possible finish

• Easy rectangular floor cut out

• Swing bracket mounting option, superior for tile or marble floors

• No messy caulking needed to meet scrub water requirements

• Plastic Boxes do not require ground bonding in most applications