Legrand AMD8 Abandonment Plugs User Manual

Legrand Hardware

Advertising
background image

RC3APTC, RC4APTC, RC7APTC,
RC9APTC, AV3APTC & AMD8APTC
Abandonment Fittings
ABPLUG3 & ABPLUG4
Abandonment Plugs

I N S T A L L A T I O N I N S T R U C T I O N S

Installation Instruction No.: 1 002 048 R3 – Updated May 2004

Walker

®

electrical systems conform to and should be properly

grounded in compliance with requirements of the current National
Electrical Code or codes administered by local authorities.

All electrical products may present a possible shock or fire
hazard if improperly installed or used. Walker electrical products
may bear the mark as UL Listed and/or Classified and should
be installed in conformance with current local and/or the National
Electrical Code.

IMPORTANT: Please read all instructions

before beginning.

Products Covered:

RC3ATC, RC3ARTTC, RC4ATC, RC4ARTTC, RC7ATC, RC7ATJTC, RC9ATC, RC9AMDTC, AV3ATC, AV3ARTTC,
AMD8ATC, AMD8ARTTC, ABPLUG3, and ABPLUG4.

Step 1 Existing poke-thru unit.

Step 2 Remove two screws in slide

holder. Remove slide holder
and attached doors.

Step 3 Attach abandonment plate

with two screws provided.

Step 4 Complete installation.

NOTE: RC3 Series shown in example. RC4, RC7, and RC9 Series

abandonment installations follow the same steps.

CAUTION: RC3, RC4, RC7, and RC9 Series must be

abandoned with receptacles installed.

CAUTION: Do not over tighten

cover mounting screws.

IMPORTANT: The internal gasket,

duplex receptacle,
and communication
modules must not
be removed to
maintain UL Listing
and Classification.

Abandonment plates are required to maintain the fire rating of the floor assembly whenever a poke-thru fitting is abandoned.
The abandonment plates in these instructions are shown in the UL Fire Resistance Directory.