1. Determine the method of feeding raceway:
S4000B for back feed, S4010B1 or S4010B2
for end feed.

2. To mount S4000 base to surface, remove
mounting screw KO’s (approx. 18" centers along
base) as required. Mount base with No. 8 flat
head fasteners.

3. To couple lengths of S4000B, insert the
G4001 coupling into one base section (cen-
tered on joint). Slide other length of base onto
coupling. Tighten locking screws.

4. For divided installations, snap G4001D
divider clip into base at 30" intervals. Snap
G4000D divider into place.

The Wiremold Company
In U.S.:
60 Woodlawn St. • W. Hartford, CT 06133-2500
1-800-621-0049 • FAX 203-232-2062
In Canada:
850 Gartshore St. • Fergus, Ontario N1M 2W8
1-800-741-7957 • FAX 519-843-5980

©1995 The Wiremold Company

INS00002 695

S4000 Stainless Steel Raceway

Typical Basic System:

5. To install device covers, snap device straps in
base as shown. Wire device and assemble to
straps. Snap device plate over base and device.

6. Cut S4000C cover to fit between device
plates. Snap in place as shown. Continue along
entire run.

A. End Blank
At end of S4000 Base run install an End
Blank. May use S4010B0 (no knockouts),
S4010B1 (1 knockout — for non-divided
installations) or S4010B2 (2 knockouts —
shown). Knockouts provided are 1/2" -
3/4" concentric style.

B. External Elbow
At 90° outside corner: Insert S4018
External Elbow onto G4001 Coupling on
S4000 Base section. Slide next base sec-
tion onto G4001 Coupling with S4018.
After wiring system, snap S4018 Cover
onto elbow and butt against S4000
Cover. Couplings are not furnished.

C. Tee
For S4000 T-branch run on same surface:
Use S4015 Tee fitting (shown) or S4015D
Tee fitting (for divided installations).
Couple to base sections with G4001 Couplings (not furnished). After wiring system, snap S4015 Cover into place and butt
against adjoining S4000 Covers.

D. Internal Elbow
At 90° inside corners: Insert S4017 Internal Elbow in end of S4000 Base section and mount section. Assemble next Base
section on S4017. After wiring system, butt S4000 Cover sections together over S4017 Base to enclose the wiring. No cou-
plings are required.

E. Flat Elbow
At 90° turn on same surface: Insert S4011 Flat Elbow into S4000 Base section and fasten screws. Assemble next Base
section on S4011. After wiring system, screw S4011 Cover onto elbow. Butt adjoining S4000 Covers. No couplings are
required.

S4010B2

1/2" Flexible
Metal Conduit

4000 Base

G4000D Sections

G4001D as Divider Clip

1 3/4"

18"

Approx.

Base Sections

G4001

Snap cover onto base

Engage one leg of cover on base

S4010B2 End Blank

S4000B Base

S4000B Base

S4000B
Base

S4018 External Elbow

S4015 Tee

S4017 Internal
Elbow

S4011 Flat
Elbow

A

B

C

D

E