Installation and operating instructions – Louroe Electronics LE-571 User Manual

Page 2

Advertising
background image

MICROPHONE CONNECTION:

If using West Penn 452 or equivalent with same color code, connect:

1. Red wire (12 Vdc) connects to terminal A of microphone terminal block
2. Black wire (audio out) connects to terminal B of microphone terminal block
3. Bare wire (ground) connects to terminal C of microphone terminal block

INSTALLATION TIP: If area to be monitored for audio is noisy or has background disturbances, the
microphone should be positioned close to the subject (4’ - 8’) if possible. Also, the microphone output can be
lowered by adjusting the gain control potentiometer. Rotating clockwise will increase the gain;
counterclockwise decreases the gain. The factory setting is 0dB output.

ELECTRICAL CONNECTION:

A represents +12 Vdc Power
B represents Audio Output
C represents Ground

A 3-pin terminal block is located on the back of the microphone housing, marked A, B, C.

CONNECTING VERIFACT BGC MICROPHONE TO A LOUROE BASE STATION OR AUDIO
INTERFACE ADAPTER

CONNECTING VERIFACT BGC MICROPHONE TO OTHER AUDIO DEVICES.

If a Louroe audio base station is not used and microphone is being connected directly to another receiver from
other manufacturers, 12 Vdc power must be applied to terminals A and C. (A is positive, C is negative).
Terminals B and C of microphone (C is common) go to the “Audio In” or “Line in” of the audio source. We
recommend shielded cable connections for terminal B and C (See last page for interconnection diagram)

INSTALLATION TIPS

1. Use 2 Cond 22AWG overall shielded audio cable only. West Penn 452, Belden 8451 or equivalent.

UNSHIELDED CABLE IS NOT SATISFACTORY FOR SOUND SYSTEMS.

2. When used at a cash register checkout, microphone should be installed closer to the customer rather than the cash

register, as the drawer sound could dominate the recording. It should be installed closest to the

area to be monitored and documented.

3. Avoid installing microphone near air vents, air conditioners, fans and other equipment that generate

high sound and air pressure.

4. If microphone is installed in a police interview room, room should be conditioned with any type of carpeting, acoustical

ceiling tiles, acoustical foam, etc. to reduce echo. This will enhance the quality of live and recorded audio.

5. The APR-1 and microphone should have a barrier or solid wall between them in order to avoid audio

feedback, especially when they are in close proximity to each other. If no barrier, microphone should be at least 25’

from APR-1 to avoid acoustical feedback.

The Verifact BGC is cylindrical, 4” dia. x 1½” H, and has four mounting holes for surface mounting to a ceiling
or other flat surface. It should be positioned so that the microphone is 4’ to 8’ from the area of desired
coverage.

All Louroe audio base stations and Interface Adapters have corresponding terminal blocks marked A, B, C.

Connect other end of cable as follows:

1. Red wire from microphone connects to pin A of Base Station (12Vdc)
2. Black wire from microphone connects to pin B of Base Station (Audio Output)
3. Bare wire from microphone connects to pin C of Base Station (Ground)

INSTALLATION AND OPERATING INSTRUCTIONS

Page 2 of 4

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

Bgc_mic-inst_12/14

®

®

®

Advertising