Electrical requirements venting requirements, Vent system chart – Maytag WED4870BW Dimension Guide User Manual

Page 2

Advertising
background image

Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical

supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit

breaker is recommended. Connect to an individual branch circuit.

ELECTRICAL REQUIREMENTS

VENTING REQUIREMENTS

Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)

diameter vent is required. Rigid or flexible metal exhaust vent

must be used. Do not use plastic or metal foil vet. Exhaust hood

must be at least 12" (305 mm) from the ground or any object

that may be in the path of the exhaust.

Determine vent path:

Select route that will provide straightest and most direct

path outdoors.

Plan installation to use fewest number of elbows and turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use as few 90° turns as possible.

Determine vent length and elbows needed for best

drying performance:

Use following Vent System Chart to determine type of vent

material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in Vent System Chart. Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

Exhaust hoods:

The Vent System charts provides venting requirements that

will help achieve best drying performance.

Vent System Chart

(Long Vent WED/WGD4870 and

WED/WGD4975 Models Only)

Number of

90° turns

or elbows

Type

of vent

Box/louvered, or

Angled hoods

1

4

3

2

0

Rigid metal

160 ft. (48.8 m)

150 ft. (45.7 m)

140 ft. (42.7 m)

130 ft. (39.6 m)

120 ft. (36.6 m)

Rigid metal

Rigid metal

Rigid metal

Rigid metal

5

110 ft. (33.5 m)

Rigid metal

Vent System Chart

Number of

90° turns

or elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

Recommended Styles:

Acceptable Style:

Louvered hood

Box hood

Angled hood