Maytag NGD7500VW Dimension Guide User Manual

Steam and non-steam electronic gas dryer, Product model numbers ngd7500v, Overall dimensions

Advertising
background image

Steam and Non-Steam Electronic Gas Dryer

PRODUCT MODEL NUMBERS
NGD7500V

Gas supply

:

This dryer is equipped for use with Natural

gas. Dryer can be converted to L.P. gas. When rigid

pipe is used it should be 1/2" IPS. When acceptable

to the gas supplier and local codes, 3/8" approved

tubing may be used for lengths under 20 ft (6.1 m).

For lengths over 20 ft (6.1 m), larger tubing should be

used. Pipe-joint compounds resistant to the action of

L.P. gas must be used. An individual manual shutoff

valve must be installed within 6 ft (1.8 m) of the dryer

in accordance with the National Fuel Gas Code ANSI

Z223.1.

Electrical

:

A 120-volt, 60 Hz, AC-only, 15 or 20 amp

fused electrical supply is required. A time-delay fuse or

circuit breaker and a separate circuit are recommended.

Water

(Steam models only)

:

The dryer must be

connected to the cold water faucet using new inlet

hoses. Do not use old hoses. Do not overtighten.

Damage to the coupling can result.

Exhaust venting

:

Exhaust your dryer to the outside.

4" (102 mm) diameter vent is required. Rigid or flexible

metal exhaust vent must be used. Do not use plastic

or metal foil vet. Exhaust hood must be at least

12" (305 mm) from the ground or any object that

may be in the path of the exhaust.

Hood styles: A & B are recommended.

The vent system chart provides venting requirments

that will help to achieve the best drying performance.

Vent system chart:

NOTE: Side and bottom exhaust installations have

a 90° turn inside the dryer. To determine maximum

exhaust length, add one 90° turn to the chart.

4"

(102 mm)

2½"

(64 mm)

4"

(102 mm)

4"

(102 mm)

B

A

A. Louvered hood
B. Box hood
C. Angled hood (acceptable)

C

14"

(356 mm)

3

7

/

16

"

(87 mm)

1"

(25 mm)

7

5

/

8

"

(194 mm)

3

3

/

8

"

(86 mm)

1"

(25 mm)

Back View

Side View

Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

Ref. W10255469B

12/2010

OVERALL DIMENSIONS

27"

(686 mm)

38"

(965 mm)

NON-STEAM - 51

1

/

2

"

(1308 mm)

STEAM - 52

9

/

16

"

(1335 mm)

NON-STEAM - 31

1

/

2

"

(800 mm)

*STEAM - 32

9

/

16

"

(827 mm)

27"

(686 mm)

38"

(965 mm)

1"*

(25 mm)

1"*

(25 mm)

0"

(0 mm)

(460 mm)

NON-STEAM - 5"*

STEAM - 5

1

/

2

"*

27"

(686 mm)

1"

(25 mm)

76"

(1930 mm)

6"

*

(152 mm)

NON-STEAM - 31

1

/

2

"

STEAM - 32

9

/

16

"

1"*

(25 mm)

5"**

(127 mm)

1"

(25 mm)

3"*

(76 mm)

3"*

(76 mm)

48"

2*

(310 cm

2

)

48"

2*

(310 cm

2

)

(800 mm)

(827 mm)

(140 mm)

(127 mm)

(229 mm)

5"

**

(127 mm)

9"*

(229 mm)

7"*

(178 mm)

7"*

(178 mm)

1"*

(25 mm)

1"*

(25 mm)

27"

(686 mm)

1"*

(25 mm)

NON-STEAM - 31

1

/

2

"

STEAM - 32

9

/

16

"

(800 mm)

(827 mm)

NON-STEAM - 31

1

/

2

"

*

STEAM - 32

9

/

16

"

*

(800 mm)

(827 mm)

Custom undercounter installation-dryer only

Dryer dimensions

† Most installations require a minimum
5" (127 mm) clearance behind the dryer for
the exhaust vent with elbow. See Installation
Instructions, “Venting Requirements.”

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

Use the fewest 90° turns possible.

Do not use vent runs longer than specified in vent length chart.

Determine the number of elbows you will need.

For closet installation, with a door, the minimum ventilation openings in the top

and bottom of the door are required. Louvered doors with equivalent air ventilation

openings are acceptable.

For cabinet installation, with a door, the minimum ventilation openings in the top

are required.

*Required spacing **For side or bottom venting, 2" (51 mm) spacing is allowed.

Vent system chart

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)