Battery-powered systems installation guidelines – Dometic 2597 User Manual

Page 16

Advertising
background image

ENGLISH

15

hvAC SySTEm pOWERED By INvERTER AND SEpARATE BATTERy BANkS WITh BATTERy SEpARATOR

NOTES:

1)

House batteries must be of the AGM dual

purpose deep cycle/starting type.

2)

Alter

nator should be upgraded. Discuss

with Dometic Applications Department

for r

ecommendation.

A

lternator

Start Battery

1

Start Battery

2

Inverte

r

-

+

+

-

+

-

HVAC Unit

-

Hous

e

Battery

2

Hous

e

Battery

3

+

-

-

+

Hous

e

Battery

4

+

Overcurrent

Protection

Battery

Separato

r

120VAC Line

DC Wiring

AC Wiring

+

-

Hous

e

Battery

1

3)

Inverter must be of appr

oved type by Dometic

in or

der to insur

e pr

oper operation of system.

4)

Cable size should be chosen based on

voltage dr

op and load. Cable to inverter

should be 2/0 gauge or gr

eater

. All cables

should have an ampacity rating of gr

eater

than the expected amp flow and/or the

over

curr

ent pr

otection device.

Battery-Powered Systems Installation Guidelines

Advertising