Measurement Computing CIO-DAS-TEMP User Manual

Page 14

Advertising
background image

First, program the 82C54 control register for CTR 1 to produce a single pulse for the duration of the
count period. Next, load an initial value equal to the period for which counts from the V/F converter will
be totaled See the previous explanation of initial count values for information on what value to load into
this counter. It works as a down-counter, the only choice available.

BASE + 1 Read - Counter 1 Current Count Register of the 82C54

Data 0

Data 1

Data 2

Data 3

Data 4

Data 5

Data 6

Data 7

0

1

2

3

4

5

6

7

Will return current count.

BASE + 2 Write - Counter 2 Load Register of the 82C54

Data 0

Data 1

Data 2

Data 3

Data 4

Data 5

Data 6

Data 7

0

1

2

3

4

5

6

7

This counter is used to sequence through multiple channels when more than one channel is read. First,
program the 82C54 control register for CTR 2 to function as a rate generator. The register at Base + 5
sets the input (prescaler) frequency for this counter.
Next, load an initial value equal to the number of clock periods between channel readings

BASE + 2 Read - Counter 2 Current Count Register of the 82C54

Data 0

Data 1

Data 2

Data 3

Data 4

Data 5

Data 6

Data 7

0

1

2

3

4

5

6

7

Will return current count.

BASE + 3 Write - Control Register of the 82C54

BCD

M0

M1

M2

RW0

RW1

SC0

SC1

0

1

2

3

4

5

6

7

The 82C54 counter is described in g reat detail in the Harris or Instel 82C54 data sheet. A brief
description of the control bits follows.

SC1

SC0

Function

0

0

Select counter 0

0

1

Select counter 1

1

0

Select counter 2

1

1

Read Command


RW1

RW0

Function

0

0

Counter latch

0

1

Read/Write least significant byte of selected counter

1

0

Read/Write most significant byte of selected counter

1

1

Read/Write least significant byte then most significant byte

10