Specifications, Analog input, Chapter 4 – Measurement Computing USB-1608FS User Manual

Page 19

Advertising
background image

19

Chapter 4

Specifications

All specifications are subject to change without notice.
Typical for 25 °C unless otherwise specified.
Specifications in italic text
are guaranteed by design.

Analog input

Table 1. Analog input specifications

Parameter

Condition

Specification

A/D converter type

16-bit successive approximation type

Number of channels

8 single-ended

Input configuration

Individual A/D per channel

Sampling method

Simultaneous

Absolute maximum input voltage

CHx IN to GND

±15 V max

Input impedance

100 M

Ω, min

Input ranges

Software-selectable

±10 V, ±5 V, ±2 V, ±1 V

Sampling rate

Scan to PC memory

0.6 S/s to 50 kS/s, software-selectable

Burst scan to 32 k sample FIFO

20 S/s to 50 kS/s, software- selectable

Throughput

Software paced

500 S/s all channels

Hardware paced (Note 1)

(100 kS/s) / (# of channels),
50 kS/s max for any channel

BURSTIO

≤ 32,768 total samples

(uses onboard FIFO)

(200 kS/s) / (# of channels),
50 kS/s max for any channel

Gain queue

Software configurable..
Eight unique, consecutive elements – one gain
element per channel.

Resolution

16 bits

No missing codes

15 bits

Crosstalk

Signal DC to 25 kHz

–80 dB

CAL output

User calibration source

0.625 V, 1.25 V, 2.5 V, 5.0 V,
software-selectable

CAL output accuracy (Note 2)

±0.5% typ, ±1.0% max

CAL current

±5 mA max

Trigger source

Software-selectable

External digital: TRIG_IN

Note 1:

Maximum throughput when scanning in hardware paced mode is machine dependent.

Note 2:

Actual values used for calibration are measured and stored in EEPROM.

Table 2. Calibrated absolute accuracy

Range

Accuracy (mV)

±10 V

5.66

±5 V

2.98

±2 V

1.31

±1 V

0.68

Advertising