DBK34A

UPS / Battery Module

Hardware Setup for 12 Volt (Default) or 24 Volt Operation …… 3
Indicators …… 4
Runtime …… 4
Charging …… 4
Fuse Replacement …… 5
Environmental Concerns …… 6
DBK34A – Specifications …… 6

DBK34A is similar to DBK34 in appearance and operation; but there are differences.
Before proceeding with this document module, verify that your device is a DBK34A. If
your device does not have the “A” suffix, use the DBK34 Document Module
instead of this
one.

Reference Notes:

o

Chapter 2 includes pinouts for P1, P2, P3, and P4. Refer to pinouts applicable to your

system, as needed.

o

In regard to calculating system power requirements, refer to DBK Basics located near

the front of this manual.


Overview

The DBK34A can power a data acquisition system in portable or in-vehicle UPS applications (both 12 V
and 24 V systems). Power storage capacity is 5 A-hr @ 12 VDC or 2.5 A-hr @ 24 VDC.

For reliable data acquisition in a vehicle, the DBK34A provides clean and consistent operating power:

• Prior to engine/generator start
• During engine start-up (battery sag due to the high-current demand of starter motor and

solenoid)

• After engine turn off.
• Before and after connection to the vehicle

DBK34A Front Panel

The DBK34A contains two sealed-lead rechargeable batteries (Gel-Packs), associated charging circuits and
current indicators. Typically, these batteries can last more than 500 full cycles and up to 10 years standby
lifetime at room temperature. Recharging is fast, and extreme temperature performance is good. The
DBK34A can be used with the LogBook, DaqBook, WaveBook, and related DBKs and WBKs. The unit’s
rugged metal package has a compatible 8×11” footprint for convenient stacking with Velcro tabs and
optional splice plates and handles for carrying.