3.2.2 Response

This portion of the command description describes the response that the user's
program should read from the serial host's COM port after sending the command. If
a response is provided, it must be read to maintain proper program seqence.

3.2.3 Bus States

This portion of the command description describes the bus command and data
transfers using IEEE bus mnemonics as listed in the following table.

Bus States

DIO lines

8

7

6

5

4

3

2

1

ATN

Attention

data

Data String

DCL

Device Clear

x

0

0

1

0

1

0

0

GET

Group Execute Trigger

x

0

0

0

1

0

0

0

GTL

Go To Local

x

0

0

0

0

0

0

1

IFC

Interface Clear

LAG

Listen Address Group

x

0

1

a

d

d

r

n

LLO

Local Lock Out

x

0

0

1

0

0

0

1

MLA

My Listen Address

x

0

1

a

d

d

r

n

MTA

My Talk Address

x

1

0

a

d

d

r

n

REN

Remote Enable

SDC

Selected Device Clear

x

0

0

0

0

1

0

0

SPD

Serial Poll Disable

x

0

0

1

1

0

0

1

SPE

Serial Poll Enable

x

0

0

1

1

0

0

0

SRQ

Service Request

TAG

Talker Address Group

x

1

0

a

d

d

r

n

UNL

Unlisten

x

0

1

1

1

1

1

1

UNT

Untalk

x

1

0

1

1

1

1

1

x = "don't care"
addrn = IEEE bus address “n”