Before you get started

Verify that you have the following items.

TempScan/1100 or MultiScan/1200

Data Acquisition CD (8.1.2 or higher)

Monitor: SVGA, 1024 x 768 screen resolution

Windows XP users

:

PC with

I

ntel

Pentium [or equivalent]; 1 GHz

512 MB memory; 10 GB disk space

Windows Vista users:

PC must be Windows Vista Premium Ready

Step 1 - Install Software

IMPORTANT ! Software must be installed first!

1. Close all running applications on the host PC.
2. Insert the Data Acquisition CD (8.1.2 or higher) into your CD-ROM drive and wait for the PC to auto-run. An Opening

Screen will appear. If AutoRun is disabled: (a) right click Windows Start menu, (b) select Explore; and (c) double-click

MasterSetup.exe. As an alternative to using the CD, you can download software from

www.mccdaq.com/software

.

3. Click the <ENTER SETUP> button.

Note: If you are downloading software from our website, follow instructions provided there.

4. From the hardware selection screen [which follows a licensing agreement], select the TempScan/1100 or MultiScan/1200, as

applicable; then follow the on-screen instructions.

NOTE: To enable all ChartView features: (a) From ChartView’s main window, open the File pull-down menu,

(b) select Authorization, (c) enter

C3523DFA6C0A

in the dialog box and apply the code.

Step 2 – Check Hardware

1. Verify that the voltage stated on the sticker [near the power switch] matches the voltage

of your intended AC power supply. If you need to change the voltage, refer to your

user’s manual.

2. Check the DIP switch, located on the rear panel. Your user’s manual discusses setting

options.

Step 3 - Connect to the Host PC

Prior to making a serial connection, make sure that the host PC’s serial

(COM) port is available and properly configured to match the DIP

switch setting in Step 2. Do this by navigating from the Windows

Desktop, i. e., Control Panel System Device Manager tab, then

clicking on Ports (COM & LPT).

Using a serial communications cable, connect the TempScan [or MultiScan] to the host

PC by one (and only one) of the following methods:

USB

Requires an adapter kit. To connect the TempScan [or MultiScan] to a USB port you will need a RS-232 to

USB Interface Adapter Kit p/n CA-232-USB-KIT (available from MCC). Refer to the associated Quick Start

document (QS RS-232_to_USB_Interface.pdf) for a list of the kit’s contents and for RS-232 to USB conversion

instructions. The pdf is included on your Data Acquisition CD (rev 8.1.2 and higher).

Use only
one of
these 3
connection
options.

RS-232

Requires a DB9F to DB9F serial communication cable. Connect the cable from the TempScan [or MultiScan]

Serial Port to a RS-232 Serial Port on the host PC.

RS-422

Requires a DB9F to DB25F serial communication cable. Connect the DB9F to the TempScan [or MultiScan]

Serial Port. Connect the DB25F to an RS-422 Serial Port on the host PC.


Note 1
:

Measurement Computing offers a CA-47 three-connector serial communications cable. The single cable has two DB9F connectors

and one DB25F connector. Note that the CA-232-USB-KIT includes a CA-47 cable.