Timecode distribution sdu/irig – Meinberg SDU User Manual

Page 5

Advertising
background image

5

Timecode Distribution SDU/IRIG

The Board SDU/IRIG was designed for the distribution of IRIG-A/B Timecode signals.
It is equipped with an adjustable input amplifier as well as twelve output buffers. The
signal outputs are available via BNC connectors. By means of signal LED's, the status of
the Board is identifiable . Due to the input amplifiers adjustable gain, the boards are
cascadable.

The SDU/IRIG contains a error detection for losing signal output, this ERROR state is
signed by the Alarm LED on the front panel, and by the ERROR output connector on
the back panel.

During "OK" State the connection of the Relay is between:

comm - on

During "ERROR" State the connection of the Relay is between:

comm - off

The SDU/IRIG is available in two different Modules

Modul TCM: Time Code modulated unbalanced

Modul TCB: Time Code modulated balanced

Specification:

Inputs:

IRIG-A/B Signal or similar timecode
with sinusoidal carrier

Input Voltage Range:

0.5V

pp

...4V

pp

Input Impedance:

50 Ohm / 600 Ohm, DC-Insulated

Outputs:

balanced or unbalanced
12 x IRIG-A/B Signal (or similar Timecode)

unbalanced

3Vpp (MARK), 1Vpp (SPACE) at 50 Ohm for IRIG
common GND for all outputs

balanced

2Vpp at 600 Ohm, with isolated BNC connector

Gain:

adjustable automatic Gain control

Connectors:
Inputsignal

1 x BNC isolated connector

Outputsignal

12 x BNC isolated connector