Microsonic mic+25/DDIU/TC User Manual

Ready start here, Instruction manual

Advertising
background image



T2

T1 + T2

Set detect distance in
mm or cm

Choose »

« for NCC or

»

« for NOC



For window mode
operation set far
detect point in
mm or cm

T1 + T2



Press T1 and T2 simultaneously for about
3 s until welcome message has passed

T1 + T2







T2

T1







T2

T1





T2

T1

T1 + T2

Set sensor-close window
margin in mm or cm

Choose rising (

) / falling (

)

output characteritic curve

T1 + T2







T2

T1

T1 + T2

T1 + T2



Set analogue output

Set sensor-distant window
margin in mm or cm

Ready

Start here





For single detect
point press T2
until »- - -« is
displayed

T1

T2









T2

T1

T1 + T2



T1 + T2





T2

Set detect distance in
mm or cm

Choose »

« for NCC or

»

« for NOC



For window mode
operation set far
detect point in
mm or cm







T2

T1

Set switched output D2

For single detect
point press T2
until »- - -« is
displayed

T1

T2









T2

T1

T1 + T2



T1 + T2





T1 + T2

T1 + T2

Set sensor parameters alternatively numerically using LED-display...

Set switched output D1

T1



T2



T1

T2





T1



T2

T1 + T2

T2



T1



Product description
 The mic+sensor with one analogue out-

put and two switched outputs measures
the distance to an object within the de-
tection zone contactless. A signal propor-
tional to distance is created and the
switched outputs are set according to the
adjusted detect distances.

 The sensor automatically detects the load

put to the analogue output and switches
to current output or voltage output re-
spectively.

 All settings are done with two push-but-

tons and a three-digit LED-display
(TouchControl).

 Light emitting diodes (three-colour LEDs)

indicate the operation conditions.

 Choosing between rising and falling out-

put characteristic as well as output func-
tion NOC and NCC is possible.

 The sensors are adjustable manually using

the numerical LED-display or may be trai-
ned using Teach-in processes.

 Useful additional functions are set in the

Add-on-menu.

 Using the LinkControl adapter LCA-2 (op-

tional accessory) all TouchControl and ad-
ditional sensor parameter settings may be
made by a Windows-Software.

Important instructions for assembly and
application
All employee and plant safety-relevant
measures must be taken prior to assembly,
start-up, or maintenance work (see operation
manual for the entire plant and the operator
instruction of the plant).

The sensors are not considered as safety
equipment and may not be used to ensure
human or machine safety!

The mic+sensors indicate a blind zone, in
which the distance cannot be measured. The
operating range indicates the distance of the
sensor that can be applied with normal re-
flectors with sufficient function reserve.
When using good reflectors, such as a calm
water surface, the sensor can also be used up
to its maximum range. Objects that strongly
absorb (e.g. plastic foam) or diffusely reflect
sound (e.g. pebble stones) can also reduce
the defined operating range.

Assenbly distances
The table below lists the minimum mounting
distances between two sensors. Smaler dis-
tances should not be used because otherwise
the sensors can influence each other.

Fig. 1:

Minimum assembly distances

Assembly instructions
 Assemble the sensor at the installation lo-

cation.

 Plug in the connector cable to the M 12

connector.

<10 cm
<30 cm

<1,0 m
<1,7 m

<60 cm

<1,6 m

<5,4 m

<16 m

<2,6 m

<30 m

A

B

Fig. 2:

Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable

Start-up
mic+ sensors are delivered factory made with
the following settings:
 Rising analogue characteristic
 Window margins for the analogue output

set to blind zone and operating range

 Switched outputs on NOC
 Detecting distances at operating range

and half operating range

 Measurement range set to maximum range

Set the parameters of the sensor manually or
use the Teach-in procedure to adjust the de-
tect points.

1
3

colour

+U

B

-U

B

brown
blue

4
2
5

D2
I/U

black
white

D1/Com.

grey

1

5

2

3

4

Fig. 3: TouchControl

Operation
mic+sensors work maintenance free. Small
amounts of dirt on the surface do not influ-
ence function. Thick layers of dirt and caked-
on dirt affect sensor function and therefore
must be removed.

Note
 mic+sensors have internal temperature

compensation. Because the sensors heat
up on their own, the temperature com-
pensation reaches its optimum working
point after approx. 30 minutes of opera-
tion.

 If the LCA-2 is connected to the mic+

when turning supply voltage on, the sen-
sors starts in communication mode and
the switched output on pin 5 of the con-
nector is not available.

 The load put to the analogue output is

detected automatically when turning
supply voltage on.

 During normal mode operation, a yellow

LED signals that the corresponding
switched output has connected.

 During normal mode operation, the mea-

sured distance value is displayed on the
LED-indicator in mm (up to 999 mm) or
cm (from 100 cm). Scale switches auto-
matically and is indicated by a point on
top of the digits. Alternatively a percent-
age scale may be set in the add-on menu.
In this connection 0% and 100% corre-
spond to the set window margins of the
analogue output.

 During Teach-in mode, the hysteresis

loops are set back to factory settings.

 In the »Two-way reflective barrier« ope-

rating mode, the object has to be within
the range of 0-85 % of the set distance.

 If no objects are placed within the detec-

tion zone the LED-indicator shows »- - -«.

 If no push-buttons are pressed for 20 se-

conds during parameter setting mode the
made changes are stored and the sensor
returns to normal mode operation.

Show parameters
Tapping push-button T1 shortly during nor-
mal mode operation shows »PAr« on the
LED-display. Each time you tap push-button
T1 the actual settings of the analogue output
and the switched output are shown.

Instruction manual

mic+ Ultrasonic Sensors with
one analogue output and two
switched outputs

c

m

m

m

%

T

1

D

1

D 2 T 2

measuring range

LED D1 and D2

3-digit
LED-display

Push-buttons T1 and T2

mic+25/DDIU/TC
mic+35/DDIU/TC
mic+130/DDIU/TC
mic+340/DDIU/TC
mic+600/DDIU/TC

2004/108/EEC