Instruction manual

lcs-Ultrasonic Sensors with
three switched outputs

lcs-25/DDD/QP
lcs-35/DDD/QP
lcs-130/DDD/QP

Product description

The lcs-sensor with three switched out-

puts measures the distance to an object

within the detection zone contactless.

Ultrasonic Sensors

Depending on the adjusted detect dis-

tance the switched outputs are set.

The output functions are changeable

from NOC to NCC.

Light emitting diodes (three-colour

LEDs) indicate the switching status.

Using the LinkControl adapter (optional

accessory) all sensor parameter settings

may be made by a Windows-Software.

Important instructions for assembly and

application

All employee and plant safety-relevant

measures must be taken prior to assembly,

start-up, or maintenance work (see operation

manual for the entire plant and the operator

instruction of the plant).

The sensors are not considered as safety

equipment and may not be used to ensure

human or machine safety!

The lcs-sensors indicate a blind zone, in

which the distance cannot be measured. The

operating range indicates the distance of the

sensor that can be applied with normal re-

flectors with sufficient function reserve.

When using good reflectors, such as a calm

water surface, the sensor can also be used up

to its maximum range. Objects that strongly

absorb (e.g. plastic foam) or diffusely reflect

sound (e.g. pebble stones) can also reduce

the defined operating range.

Assembly instructions

Assemble the sensor at the installation

location.

Plug in the connector cable to the M 12

connector.

Fig. 1: Pin assignment with view onto sensor

plug and colour coding of the

microsonic connection cable

Assembly distances

The assembly distances shown in Fig.2 for

two or more sensors should not be fallen

below in order to avoid mutual interference.

Fig. 2: Assembly distances

1
3

colour

+U

B

-U

B

brown
blue

4
2
5

D2
D1

black
white

D3/Com.

grey

1

5

2

3

4

3x

>10 cm
>30 cm

>1,0 m
>1,7 m

>60 cm

>5,4 m

A

B

Start-up

lcs sensors are delivered factory made with

the following settings:

Switched outputs on NOC

Detecting distances at operating range

and half operating range

Measurement range set to maximum

range

Set the parameters of the sensor using the

LinkControl Adapter LCA-2 and the

LinkControl software.

Operation

lcs-sensors work maintenance free. Small

amounts of dirt on the surface do not influ-

ence function. Thick layers of dirt and caked-

on dirt affect sensor function and therefore

must be removed.

Note

lcs-sensors have internal temperature

compensation. Because the sensors heat

up on their own, the temperature com-

pensation reaches its optimum working

point after approx. 30 minutes of opera-

tion.

During normal mode operation, a yel-

low LED signals that the corresponding

switched output has connected.

You can reset the factory settings at any

time, see »Lock Teach-in & factory set-

ting«

.

lcs-sensors optional can be programmed

using the LinkControl adapter LCA-2,

see

«Optional setting of parameters

using the LinkControl Adapter LCA-2» ,

«Download of sensor parameters in

the LCA-1» and

«Upload of sensor

parameters back to the sensor».

*B7300*

MV-DO-074381-187012

89/336/EEC

Factory setting

Reset to factory setting

Turn supply voltage OFF

Turn supply voltage ON

while »D3/Com«

is connected to -U

B

Keep »D3/Com« connec-

ted to -UB until both LEDs

stop flashing (ca. 13 sec)

Normal mode operation

Download of parameters completed

Current mearsurement value is displayed

Press

at the LCA-2 simultaneously (ca. 1 sec)

F

T2

+

Download of sensor parameters in the LCA-1

1

F + T2

Parameters are transfered from the sensor to the LCA-2

R

Press

at the LCA-2 (ca. 1 sec)

R

Upload of sensor parameters back to the sensor

Upload of parameters completed

Current mearsurement value is displayed

Press

at the LCA-2 simultaneously (ca. 1 sec)

F

T1

+

F + T1

Parameters are transfered from the LCA-2 to the sensor

R

Press

at the LCA-2 (ca. 1 sec)

R

3