Section 1

SPECIFICATIONS

Power Input ....................................................................... 115 VAC 50/60 Hz.

Weight ......................................................................................... 6 3/4 pounds

Shipping Weight ................................................................................ 8 pounds

For Use with Torch Numbers ................................................ 146-XXX, 216-XXX

Section 2

SUPPORT EQUIPMENT REQUIRED

C. V. or C.C. power source of sufficient capacity for your needs.

Regulated gas supply and hoses.

Properly sized power lead from power source to ground.

Section 3

OPTIONAL KIT

CV POSA START ADAPTOR KIT
005-0339
Used only when having arc starting problems with a CV power source.

Section 4

OPTIONAL ACCESSORY

SECONDARY CONTACTOR BOX
001-3066
Used in conjunction with the WC-1 on power sources that do not have a
contactor system. Mounts on top of the WC-1 and is rated at 200 amps, 100%
duty cycle.

Section 5

INSTALLATION

Location

The WC-1 should be secured to the power supply or another suitable locations
where it can be secured to protect it from damage. Lead lengths and
accessibility to a 115 VAC 50/60 Hz power source must also be considered
when installing the control. Refer to specifications for dimensional information.

Contactor Selection

The WC-1 is shipped from the factory in the closing contacts position. A six
foot contactor/Posa Start sense cable is supplies with the unit to which the
black and white wires supply the contactor signal.

NOTE:

Refer to the power supply owner's manual for location of

and type of contactor signal required.

WARNING:

Disconnect the WC-1 from all power sources before changing contactor.

If a 115 VAC signal is required, remove the four screws from both sides on the
control box, and remove cover. Locate black and white wire on #3 and #4 of
terminal strip J6. Move black wire to #4 and white wire to #3 of terminal strip
J5. The unit will now supply 115 VAC on the black (hot) and white (neutral)
wires.