Flow chart – MK Products CobraMig 260 PS/Feeder User Manual

Page 26

Advertising
background image

CobraMig 260 Owner's Manual - Page 20

FLOW CHART

TROUBLE:
No wire feed at torch, feeder not operating, ie. No slave motor or brake solenoid action.

CAUSE:
(F3) 2 amp Fuse on Main P.C. board on wire feeder.
(F1) 4 amp Fuse on Main P.C. board on wire feeder.
Micro Switch defective / Not being activated.
Broken electrical cable.
Transformer relay, Relay K2 inoperative.
Loose J2, J3, Cobra I Main P.C. board connections.

START

NO

YES

YES

NO

1

1

SYMPTOM

NO WIRE FEED AT TORCH, FEEDER NOT OPERATING

PROBLEM AREA

COBRA I: MAIN BOARD, K2 RELAY

TORCH:

MOTOR, CABLE, MICRO SWITCH, SLAVE MOTOR, BRAKE SOLENOID

BRAKE SOLENOID OR

SLAVE MOTOR DEFECTIVE

GO TO FLOW CHART #4
COBRA I MAIN BOARD, F1 AND
F3 FUSES ARE OK BUT WIRE
FEED AND TORCH NOT
OPERATING

GO TO FLOW CHART # 3
COBRA I MAIN BOARD, F1
FUSE IS BLOWN

GO TO FLOW CHART # 2
COBRA I MAIN BOARD, F3
FUSE IS BLOWN

MICRO SWITCH, TRANSFORMER
RELAY, OR K2 RELAY ON COBRA
I MAIN BOARD IS DEFECTIVE OR
LOOSE J2, J3 ON COBRA I PC BOARD

MOTOR LEADS
SHORTED OR TORCH
MOTOR IS DEFECTIVE

IS COBRA I MAIN

BOARD F3 FUSE OK?

IS COBRA I MAIN

BOARD F1 FUSE OK?

Advertising