Technical Specifications

Wire Capacity
.030" - .045" (0.6mm - 1.2mm) solid and hard wire
.030" - 1/16" (0.8mm - 1.6mm) aluminum and cored wire

Wire Speed
800 IPM (20.3 mpm) max at rated feeder input voltage (120VAC / 42VAC)

Duty Cycle - 100%
All ratings are using Argon gas
200 Amps/25 Volts

Air cooled standard

225 Amps/25 Volts

Water cooled standard

300 Amps/25 Volts

Water cooled using optional W/C barrel

(P/N 003-2104)

400 Amps/25 Volts

Water cooled using optional W/C barrel & cup

(P/N 003-2104 & 621-0065)

Shipping Weight (approximate)
Air Cooled

15ft. (4.5m) ....................................... 13.09 lbs. (5.94 Kg)
25ft. (7.6m) ....................................... 19.29 lbs. (8.29 Kg)
50ft. (15.2m) ..................................... 29.9 lbs. (13.19 Kg)

Water Cooled

15ft. (4.5m) ....................................... 13.59 lbs. (6.16 Kg)
25ft. (7.6m) ....................................... 19.69 lbs. (8.93 Kg)
50ft. (15.2m) ..................................... 34.79 lbs. (15.78 Kg)

Torch weight (less leads)

Air/Water cooled - 2.5 lbs. (1.13 kilogram)
Water cooled - 2.6 lbs (1.18 kilogram) with optional W/C barrel

Support Equipment Required

C.V. or C.C. power source of sufficient capacity for your needs.

Regulated gas supply and hoses.

Properly sized power leads from power source to wire feeder and ground.

Water source and hose capable of providing a minimum of

1 quart

(.95 liter) / min. at 45 p.s.i. when using water cooled torches.

Coolant Recommendations

Use a name-brand additive, which does not contain reactive sulphur or

chlorine and does not react with copper, brass or aluminum or create a

custom mix using this formula:

Use 3 Gallons (11.4 Liters) distilled water.

Use 1 Gallon (3.8 Liters) ethylene glycol.

Use 1 tsp (5 ml) liquid glycerin

The Coolant rate should be 1 quart (.95 liter) / minute at 35 p.s.i.