Features operating procedure – MK Products Positioner #2 User Manual

Page 8

Advertising
background image

#2 Positioner - Owner's Manual

Page 1

FEATURES

OPERATING
PROCEDURE

1. Connect positioner to 115 VAC power source.

2. Connect welding ground cable to grounding lug assembly on positioner.

3. Set high/low range switch to proper position.

4. Set forward/reverse switch to proper position.

5. Establish desired speed setting using the rheostat on the positioner.

6. Depress foot control to activate positioner.

NOTE: Failure to attach the welding ground cable to the grounding lug assembly

will result in damage to the positioner electrical circuit.

Tilt Release/
Locking Knob

Foot Control
Rheostat

Stepless
Speed
Control

Fuse

Forward/
Reverse
Switch

High/
Low
Range
Switch