Thermostat

Spark

Gas valve

Flame detector device

Lock out indication

TW TS

TS TWI TS TWI TS

WORKING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM

WORKING DIAGRAM

TECHNICAL SPECIFICATIONS

Classifi cation codes according to EN298

A-M-R-V-X-K

Class of protection according to Low Voltage Directive

IP-20

Waiting time / TW

8 s

Safety time / TS

45 s

Inter-waiting time / TWI

120 s

Working temperature

–20°C to +45°C

Nominal working voltage*

12 - 13,8V DC

Resistance to vibration according to

EN60068-2-6:1995

*Functional approved at a voltage variation of +20% through –25%