SYSTEM CHECK
MILLIVOLT VALVES

Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.

Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.

Slide the button to OFF. The flame should extinguish (the pilot flame will remain on).

Slide the button to REMOTE (the center position), and then press the ON button on the transmitter to turn the system to ON. The
main gas flame should ignite.

Press the OFF button on the transmitter to turn the system to OFF. The flame should extinguish (the pilot flame will remain on).

Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to
a temperature of a least 2

0

F (1

0

C) above the ROOM temperature displayed on the LCD screen. With this manual setting, the

normal thermostatic cycle is overridden and the system flame will ignite. Set the SET temperature to at least 2

0

F (1

0

C) below the

room temperature and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle to on and off
thermostatically approximately every two minutes as the ROOM temperature changes, but only when the temperature differential
between ROOM and SET temperatures differ at least 2

0

F (1

0

C). The 2

0

F differential is the factory setting.


ELECTRONIC IGNITION SYSTEMS

Slide the 3-position button on the remote receiver to the ON position. The spark electrode should begin sparking to ignite the pilot
(the pilot may ignite after only one spark). After the pilot flame is lit, the main gas valve should open and the main gas flame
should ignite.

Slide the button to OFF. The main gas flame and pilot flame should BOTH extinguish.

Slide the button to REMOTE (the center position), and then press the ON button on the transmitter to turn the system to ON. The
spark electrode should begin sparking to ignite the pilot. After the pilot is lit, the main gas valve should open and the main gas
flame should ignite.

Press the OFF button on the transmitter to OFF. The main gas flame and pilot flame should BOTH extinguish.

Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to
a temperature of at least 2

0

F (1

0

C) above the ROOM temperature displayed on the LCD screen. With this manual setting the

normal thermostatic cycle is overridden and the system flame will ignite. Set the SET temperature to at least 2

0

F (1

0

C) below the

room temperature and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle to on and off
thermostatically approximately every two minutes as the ROOM temperature changes, but only when the temperature differential
between ROOM and SET temperatures differ at least 2

0

F (1

0

C). (The 2

0

F differential is the factory setting).

CP (CHILDPROOF) FEATURE

This SKYTECH remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operation of the
appliance, from the TRANSMITTER.

SETTING “LOCK-OUT” –(CP)

To activate the “LOCK-OUT” feature, press and hold the ON button and the MODE button at the same time for 5 seconds. The
letters CP will appear in the TEMP frame on the LCD screen.

To disengage the “LOCK-OUT”, press and hold the ON button and the MODE button at the same time for 5 seconds and the letters
CP will disappear from the LCD screen and the transmitter will return to its normal operating condition.

To verify that transmitter is in the CP lock-out mode press any key and the LCD screen will show “CP”


NOTE: If the appliance is already operating in the ON or THERMO MODES, engaging the “LOCK-OUT” will not cancel the operating
MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANSMITTER. If in the auto modes, the THERMO
operation will continue to operate normally. To totally “LOCK-OUT” the operation of the TRANSMITTER’S operating signals; the
transmitter’s MODE must be set to OFF.

THERMO UPDATING FEATURE –TRANSMITTER – (T/S –TX)

This SKYTECH remote control has a THERMO UPDATING Feature built into its software. The THERMO UPDATING Feature operates
in the following manner, but only in the THERMO MODES:

The transmitter reads the ROOM temperature every 2 minutes checking the ROOM temperature against the SET temperature
and then sends a signal to the receiver.