Installation – Montigo RX200 User Manual

Page 5

Advertising
background image

Installation

Page 5

XT0016 - 092214

C. Control Module Installation:
1. Position the new control module on the fireplace floor ( the red

switch "SW1" must be towards the front of the fireplace).

2. Connect the Power Plug to X1

Figure 14

New Control Module

3. Connect the Spark and sensor wires to X2 and X3
4. Connect the Manual ON/OFF switch to X4
5. Connect the Valve Harness to X5
6. Connect the Stepper motor harness to X6
7. Attach the Control module to the bottom of the

firebox using the velcro strips supplied.

Figure 15

X1 plug on control module

Figure 16

X2 > X6 plugs on control module

Advertising