EDVPV47-58 Power Vent System

Part No. XG0700 - 090909

Installation

WARNING

:

Montigo will not be held responsible for any water damage

that may occur from not installing the equipment as specified

by this document.

Figure 11. Conduit and Wiring Clearances.

Wiring Installation

Connect the wiring to the external power vent termination as outlined
in the previous section, and connect the wiring to the fireplace as
outlined in the schematic below. Ensure that the proper clearances are
maintaned for the wiring and conduit.

When installing the wiring it must never run above the vent run

and it must be at least 1" clear of all venting.

1" min.

Vent

Cable

Figure 12. Wiring Diagram for Optional 24V to Millivolt Relay.

White

Red

Black

Milivolt wiring

to Valve

24V wiring from

PV System

Termination

Inner direct vent pipe

6. Install and screw the frame asssembly in place, and ensure that

the frame is level.

7. Install the termination to the frame assembly by first connecting

Figure 10.

Securing the Termination to the Frame Asssembly.

Figure 10a.

Installing the Sealing Ring.