Installation, Wiring, Installing the log set – Montigo MW38 BV User Manual

Page 6: Gas control and pilot wiring, Wiring for the optional fan kit

Advertising
background image

Page 6 of 13

MW38-BV Modular Fireplace

XG0310 Rev. 01 - 11/98

Installation

Wiring

Figure 8b. Wiring schematic for optional fan kit.

Figure 8a. Wiring for optional air circulating fan kit.

G

L1-WH

L2-BLK

Quick Connect

plug to motor

Installing the Log Set

The MW38-BV is supplied with four (4) soft fibre logs. Logs "A" and
"B" are permanently attached to a fibre base, which is pre-installed by
the factory. To install the two small logs ("C" and "D"), simply place
them onto their mating positions as shown in figure 9a below. When
log set is installed it should look like figure 9b.

Figure 9a. Log placement.

Figure 9b. Completed log installation.

Log 'C'

Logs 'A' and 'B'

Log 'D'

NOTES

:

If logs are not placed properly, excessive sooting will result.
If handling or vacuuming the logs, do not attempt to move

the two large logs. They are extremely fragile, and will break

easily.
The surface of the logs will crack due to the heat from the

flames. This is a normal occurance.

Gas Control and Pilot Wiring

MW38-BV-I

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Fuse

Limit

Switch

Wall

Switch

Fan Plug

Receptacle

Junction Box

Junction Box Cover

White

Black

Green

40 VA

Transformer

115VAC

24VAC

Grnd Screw

Figure 7. Wiring for the MW38-BV-I with Honeywell gas control and

pilot.

Wiring for the optional Fan Kit

All 38 Series Modular fireplaces may be equipped with optional fan or
blower kits for circulating heat into the living space.

Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.

Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.

For more information see the Fan Kit Installation Guide included
with the fan kit.

NOTE:

If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.

115/1/60 Supply

G

L1 L2

Advertising