RT-3020 User Guide - Rev. E

C

Event Input Configuration

Figure D1 details the wiring of the Event/Can cable
assembly NavCom part number P/N 94-310062-3003.

Refer to Chapter 2, Event for detailed electrical
specifications.

Table D1 details the wiring configuration required for
Event-Hi, and Event-Lo pulse sensing.

Figure C1: Event Cable Wiring Diagram

Pin #

Signal

Name

Event Sync Wiring

1

Event Lo

Tie Event-Hi to Ground

2

Event Hi

Tie Event-Lo to Ground

3 Ground

N/A

Table C1: Event Wiring Connections

Once the cable is wired to correspond with the event
pulse requirements, the receiver must be configured to
output the message containing a time mark, referenced
to the time kept within the receiver, indicating when
the event is sensed.

C-45

Advertising
This manual is related to the following products: