6.5.2 Example 2

Figure 6.4 Point to point 8 out and 8 back.- 2 Modules, 2 sites.

Both modules are used for embedding and de-embedding and the SDTI signal is connected in a

loop so one of the modules must be the clock master.

Table 6.7 Local module

Port Directions

SW2 1-3 off, on, off

Master clock mode SW2.6 on
Demux start address SW1 1-4 off, off, on , off

Mux start address

SW1 5-8 off, off, off, off

Table 6.8 Remote module

Port Directions

SW2 1-3 off ,on ,off

Demux start address SW1 1-4 off, off, off, off

Mux start address

SW1 5-8 off, off, on , off