5.2 GPI Alarm

– Module status outputs

These outputs can be used for wiring up alarms for third party control systems. The GPI
outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI
connector is shown in figure below.

GPI pinning

Signal

Name

Pin # Mode

Status

General error status for the
module.

Pin 1 Open Collector

LOS

Loss of optical signal

Pin 2 Open Collector

LINK

Ethernet electrical link

Pin 3 Open Collector

LASER

Laser fail

Pin 4 Open Collector

Ground

0 volt pin

Pin 8 0V.

Electrical Maximums for GPI outputs

Max current: 100mA

Max voltage: 30V

Figure 6