3 xy mode, 4 power alarm, 5 power up mode – Nevion SL-D32P+ User Manual

Page 10

Advertising
background image

SL-D32P+

Rev. F


nevion.com | 10

3.2.3 XY Mode

If The SL-D32P+ Ported Data Router is to be configured as a D1616, D3232, D4848 or
D6464 router, this DIP must be ON. In this mode SL-D32P+ will be identical with the
existing VikinX D1616 and D3232 Data Router.

SW 6

D1616 mode

OFF

Ported mode

ON

XY mode

Default mode is OFF.

The RS422 ports on the SL-D32P+ are labeled from 1 to 32. When multiple routers are
connected together to form a bigger router, the ports are used as the tables below.

In ported mode:

Ext Address

Port

Combined router port

0

1-32

Port 1-32

1

1-32

Port 33-64

2

1-32

Port 65-96

3

1-32

Port 92-128

In XY mode:

Ext Address

Port

Destination oriented

Source oriented

0

1-16

Source 1-16

Destination 1-16

0

17-32

Destination 1-16

Source 1-16

1

1-16

Source 17-32

Destination 17-32

1

17-32

Destination 17-32

Source 17-32

2

1-16

Source 33-48

Destination 33-48

2

17-32

Destination 33-48

Source 33-48

3

1-16

Source 49-64

Destination 49-64

3

17-32

Destination 49-64

Source 49-64

3.2.4 Power alarm

When using redundant power supply, the power alarm should be ON.

The SL-D32P+ will give alarm, and the front LED will blink red, when one of the power
supplies connected fails.

If only one power supply is connected, this DIP must be off.

SW 7

Router orientation

OFF

Disable Power Alarms

ON

Enables Power Alarms

Default mode is OFF.

3.2.5 Power up mode

Switch 8 on the configuration switch defines the power up mode. The SL-D32P+ router
provides two modes for powering up the system.

Mode 1 switches all ports are disconnected.

Mode 2 switches all ports according to the latest setting buffered in the routers processor
system.

The power up mode can be switched according to the following pattern:

SW 8

Power Up mode

OFF

Mode 2

ON

Mode 1

Default is OFF.

Advertising