4 installation drawings, Aa37-212, Aa37-001 – Northern Airborne Technology AA37 User Manual

Page 13

Advertising
background image

SM39 Rev. 4.00

AA37 Series Alerting System Manual

Nov 10, 2003 Page 2-3

ENG-FORM: 805-0106.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

2.3.4.5 Alert

2

a)

Activate the AA37 Alert 2 trigger circuit. There should be an intermittent (hi/lo)
tone with no unusual noises or disruptions heard in the headset. Reset the AA37
Alert 2 trigger circuit.


b)

Activate the second AA37 Alert 2 trigger circuit, if installed. There should be an
intermittent (hi/lo) tone with no unusual noises or disruptions heard in the
headset. Reset the AA37 Alert 2 trigger circuit.


c) Repeat

steps

2.3.4.5 a) and b) for the copilot’s headset, if the feature is used in

the installation.


2.3.4.6

Alert 3 (AA37-212 only)


a)

Activate the AA37 Alert 3 trigger circuit. There should be a swept tone of 1 to 3
seconds duration, with no unusual noises or disruptions heard in the headset.
Reset the AA37 Alert 3 trigger circuit.


b)

Activate the second AA37 Alert 3 trigger circuit, if installed. There should be a
swept tone of 1 to 3 seconds duration, with no unusual noises or disruptions
heard in the headset. Reset the AA37 Alert 3 trigger circuit.

c) Repeat steps 2.3.4.6 a) and b) for the copilot’s headset, if the feature is used in

the installation.


2.4

Installation

Drawings


DRAWING REV.

DESCRIPTION

TYPE


AA37\212\403-0 1.02

Alerting

System

Interconnect


AA37\212\405-0

1.01

Alerting System

Connector Map


AA37\212\922-0 1.00

Alerting

System

Mechanical


AA37\001\403-0 1.01

Alerting

System

Interconnect


AA37\001\405-0

1.00

Alerting System

Connector Map


AA37\001\922-0 1.00

Alerting

System

Mechanical



Advertising