2.3.3

Post-Installation Checks

2.3.3.1 Voltage/resistance

checks


Do not attach the VR33 to the PA250 or PA700 until the following conditions are
met.


Check the following (one connector for VR33-001, two for VR33-002):

a)

Check J5 and J6 pin <B> for continuity to ground (less than 0.5

Ω).

b)

Check P6 (aircraft power connector) pin <A> for +28 Vdc relative to ground.

c)

Install P6 to J6 (VR33 connector), and then check J5 (PA connector) <A> for
+33 Vdc relative to ground.


2.3.3.2

Power On checks


Install the VR33 and power up the system. Verify normal operation of all functions with
reference to all system components.

Note: To verify proper operation, all functions and levels should be checked in-flight (if

appropriate).

Upon satisfactory completion of all performance checks, make the required log
entries and complete the necessary Regulatory Agency paperwork before
releasing the aircraft for service.

2.4

Continued Airworthiness

Maintenance of the VR33 is ‘on condition’ only. Periodic maintenance of this product is
not required.

2.5

Installation Drawings

DRAWING REV.

DESCRIPTION

TYPE

VR33-001

VR33\001\922-0

1.01

DC Power Converter

Mechanical Installation

VR33-002

VR33\00

2

\922-0 1.00 DC Power Converter Mechanical Installation