2 physical specifications, 3 environmental specifications, 4 product approval – Northern Airborne Technology AMU50-001 User Manual

Page 11

Advertising
background image

AMU50-001 Audio Management Unit

SM76 Installation and Operation Manual


Section 1 Rev: 1.03

Issue 1

Page 1-8

ENG-FORM: 800-0116.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

1.4.2

Physical Specifications

Height:

56.6 mm (2.23 in) maximum

Depth:

279.4 mm (11.00 in) maximum

Width:

190.0 mm (7.48 in) maximum

Weight:

2 kg (4.4 lbs) maximum

Material and Finish:

Conversion coated aluminium

Connectors:

Four 50 pin D-Sub, two male and two female

Jack post locking hardware

Installation:

RS-422 Cable:

20.0 m (785.9 in) maximum

RM01 Cable:

0.3 m (11.8 in) maximum

MIC Cable:

5.0 m (196.7 in) maximum

PHN Cable:

5.0 m (196.7 in) maximum

USB Cable:

See USB 2.0 Specification

Mounting:

Bulkhead Mount: Four 10-32 screws

1.4.3

Environmental Specifications


The AMU50-001 has been tested to the environmental conditions listed below. Environmental categories
for which TSO and ETSO compliance has been demonstrated are listed on the Environmental
Qualification Form in Section 2 of this manual.

Temperature:

-40 to +70

° C (Operating)

-45 and +85

° C (Short Time Operating)

-55 to +85

° C (Ground survival)

Altitude:

50,000 feet max

Humidity: 95%

non-condensing

Shock:

Operational Shock; 6 g for 11 ms

Crash Safety (impulse); 20 g for 11 ms

Crash Safety (sustained); 20 g for 3 s

Vibration:

RTCA/DO-160E category [(SBM)(U2FF1)]

1.4.4

Product Approval

1.4.4.1

FAA: TSO-C139


When configured as defined in section 1.4.5 (DACS System Equipment) the Digital Audio Communication
System is approved as follows:

FAA: TSO-C139 (RTCA/DO-214 Class Ib, RTCA/DO-160E, RTCA/DO-178B Level C)