6 accessories required but not supplied, 7 installation drawings – Northern Airborne Technology 246 User Manual

Page 12

Advertising
background image

Model 246 Isolation Amplifier

SM246 Installation and Operation Manual

Section 2 Rev: 1.00

Issue 2

Page 2-6

2.5.2.1

Jumper Adjustments

Access to the jumper is by cover removal. Refer to Assembly drawing 246-1 in the SM246 Maintenance
manual. To remove the Model 246 cover, remove the 4 screws in the sides of the unit (do not remove
screws under the base of the unit). Lift the cover to remove. Reinstall the cover by following the same
steps in reverse order. Tighten all screws securely but do not over-tighten.

CAUTION

The Model 246 Series Isolation Amplifier contains static sensitive

devices. Proper ESD handling procedures must be followed to prevent

damage to the unit.

An internal jumper J1 allows the installer to apply a 30 mA microphone bias current to pins A and C. The
microphone may be connected between pins A and B or pins C and B. This makes the Model 246
compatible with the Model 210 Voice Activated Switch.

Note: The Collins unit provides only 5 mA bias current.

When jumper J1 is connected between P2 pins 1 and 2 (closest to connector), the microphone bias current
is enabled. When it is connected between pins 2 and 3 (furthest from the connector), it is disabled.

Pin 3

Pin 2

Pin 1

2.6

Accessories Required But Not Supplied

To complete the installation, a 246-IKC crimp Installation kit, NAT Part # C16S-1-IKC, is required. The kit
consists of the following:

NAT Part #: C16S-1-IKC

Quantity

Description

NAT Part #

1

Circular Socket, Crimp, Bulkhead

20-33-944

2.7

Installation Drawings

DRAWING REV.

DESCRIPTION TYPE

SERIAL

No.

246

246\246\246 1.41

Isolation

Amplifier

Outline

All

246\246\521-0

1.00

Isolation Amplifier

Environmental Qual Form

All

Section 2 ends following the above documents