Osburn OB01111 User Manual

Page 6

Advertising
background image

6

MANUFACTURED (MOBILE) HOME INSTALLATIONS – ADDITIONAL
REQUIREMENTS

1. The stove must be bolted to the floor (secure the unit by prying out the two plastic

plugs in the pedestal, and installing the two 3/8" x 3-1/2" (9.8mm x 88.9mm) lag
bolts through the holes provided).

2. The unit

must

be provided with outside combustion air.

3. Clearance from the top of stove to an unprotected ceiling should be a minimum of

52” (1321mm).

4. The stove must be used connected to the chimney with listed double wall connector

of 6" (152 mm) diameter.

5. The chimney system must be a minimum of 12' (3658 mm) in height from the

hearth pad to the top of the chimney assembly.














Figure1.1 Necessary installation components.

Note: For manufactured home installations in the USA, the stove must be grounded to the

frame of the home using a # 8 ground wire with approved terminations and star lock
washers.


C

AUTION

:

T

HE

S

TRUCTURAL

I

NTEGRITY

O

F

T

HE

M

ANUFACTURED

H

OME

F

LOOR

,

W

ALL

,

C

EILING

/

R

OOF

M

UST

B

E

M

AINTAINED

.

C

AUTION

:

D

O

N

OT

I

NSTALL

I

N

A

S

LEEPING

R

OOM

.

TYPICAL MOBILE

HOME INSTALLATION

RAINCAP

FACTORY BUILT CHIMNEY

STORM COLLAR

ROOF FLASHING

SUPPORT/SHIELD

CHIMNEY ADAPTOR

DOUBLE WALL CONNECTOR

DOUBLE WALL 45° ELBOW

OSBURN 1100

Advertising
This manual is related to the following products: