4.Quick Start

13

(3) Set the output voltage to the maximum rating.
(4) Turn on the channel output. The ON/OFF and Curr/CC key is lighted, which

indicates the channel you opened is in Constant Current output mode.

(5) In each working mode, set some different current values; check if the actual current

value displayed is close to the set current value, and to check if the actual voltage
value displayed is nearly zero.

(6) Check that if the output current can be adjusted from zero to the maximum rating.
(7) Turn off the channel output and remove the short wire from the output terminals.

4.5 Working Mode

ODP Series are designed with four working modes: Independent, Parallel, Series and
Plus-minus. Press the Mode key to switch between the four working modes. For the
instructions of the user interfaces in the four working mode, please see "User Interface"
on P7.

4.5.1 Icons and Ratings

The status icons and voltage/current ratings of the four mode is listed below.

Independent

Parallel

Series

Plus-minus

Status Icons

Voltage rating 0~30V

0~30V

0~60V

0~±30V

ODP3032

Current ratings

0.02~3A

0.1~6A

0.02~3A

0.02~3A

ODP3052

Current ratings

0.02~5A

0.1~10A

0.02~5A

0.02~5A

The 5V output terminals always output fixed 5V during the instrument is powered on, the
max output current is 3A (ODP3032) or 5A (ODP3052). Users could choose the proper
mode and output terminals as required.

4.5.2 Connections

Take ODP3032 for instance:

Independent