Caring for your water heater, If you need service, Service error code chart (cont.) – Paloma PHH-32 part 1 User Manual

Page 26: Call for assistance, Service information, Care instructions

Advertising
background image

26

Error Code

Possible Cause

Solution

1L

Water heater has buildup of lime deposits.

Contact a dealer or qualified service

technician.

05

Air intake or vent exhaust opening may be

blocked.

Remove any blockage. (Air intake requires

12 in. [30 cm] of clearance.)

The vent pipes on the vent termination

may not be connected properly.

Contact a dealer or qualified service

technician.

11

The gas shut-off valve is not fully opened.

Check shut-off valve and open completely.

12

Gas service has been interrupted.

Contact your gas utility company.

LP gas is running low (LP models only).

Refill or replace your LP gas container.

13

If this code is still displayed after taking

the numbered steps above.

Contact a dealer or qualified service

technician.

14

Water heater is overheating.

Contact a dealer or qualified service

technician.

15

The heat exchanger is too hot.

Check for blockage in the vent. Contact a

dealer or qualified service technician.

29

Neutralizer is clogged.

Contact a dealer or qualified service

technician.

31

Faulty inlet thermistor.

Contact a dealer or qualified service

technician.

33

Faulty outlet thermistor.

Contact a dealer or qualified service

technician.

61 or 99

Faulty blower motor.

Contact a dealer or qualified service

technician.

65

Faulty water flow solenoid.

Contact a dealer or qualified service

technician.

92

The neutralizer needs to be replaced soon. The unit can be used for a while, but

contact a dealer or qualified service

technician.

93

The neutralizer must be replaced.

The unit cannot be used until the neutral-

izer is replaced. Contact a dealer or quali-

fied service technician.

P1

Not enough water flow to operate the unit.

Increase the water flow from the fixtures.

Service Information

Service Error Code Chart (cont.)

Care Instructions

CARING FOR YOUR WATER HEATER

1.

All questions, adjustments, repairs, and/or

routine maintenance should be directed to

your installer, plumbing contractor, or licensed

service agent. If your contacts have moved or

are not available, please refer to the telephone

directory, commercial listings, or local utility

company for qualified service assistance.

2.

If your problem has not been solved to your

satisfaction, contact the Rheem National

Service Department at the following address:

Rheem
National Service Department
1241 Carwood Court
Montgomery, Alabama 36117
Phone: 1-800-432-8373

When contacting the manufacturer, the

following information will be requested:

A.

Model and serial number. (See page 8 or the

ratings plate on the front of the water heater.)

B.

Address where the water heater is located.

C.

Name and address of installation contractors

(page 8) and all qualified service companies

that have worked on the water heater.

D.

Original installation date. (See page 8.)

E.

Dates any service or preventive maintenance

was performed.

F.

Details of the persisting problem.

G.

List of businesses that have tried to fix this

problem, along with dates of service.

Call for Assistance