Plus, Reference manual - zone 1 and zone 2 configuration, Zone 1 and zone 2 – Paso Sound DMS120P User Manual

Page 9: Zone 1 and zone 2 wiring diagram example, Zone 1 mic input 15 watt output, Rvc+ master

Advertising
background image

plus

DIGITAL MULTI SERIES

MEDIA

REFERENCE MANUAL - ZONE 1 AND ZONE 2 CONFIGURATION

ZONE 1 AND ZONE 2

BLOCK DIAGRAM

ZONE 1 AND 2 DIP SWITCH PROGRAMMING

RF 006

Z1 01 Z1 02 Z1 03

Z2 U4 Z2 P5 Z2 I6 Z2 I7 Z2 I8 Z2 I9 Z2 M10 Z2 MV11 Z2 P12

ON

OFF

1. Input 8
2. Input 9
3. Module

4. Zone2
Unmute
5. Pre-Out
6. Input 6
7. Input 7

8. Input 8
9. Input 9
10. Module
11. MIC VOX
12. PHANTOM

MOH - ZONE 1

ZONE 2

OUTPUT

LEVEL

MIC

LEVEL

ZONE 2

MOH

LEVEL

ZONE 1

LEVEL

MOH - ZONE 1

VOX

RELAY

TRIGGER

CHIME

SELECT

TRIGGER

ZONE 1 AND ZONE 2 WIRING DIAGRAM EXAMPLE

DIP

CONTROL

SWITCHES

70V Speaker

70V Speaker

70V Speaker

MOH LEVEL

ZONE 2

OUTPUT LEVEL

ZONE 1 LEVEL

MIC

LEVEL

0

600 OHM

0

8 OHM

0

8 OHM

70 VOLT

G

COM

HOT

UNMUTE

MASTER RVC+

ZONE 1 OUTPUT

ZONE 2 OUTPUT

MIC INPUT

UNMUTE

MIC VOX

INPUT 8
INPUT 9
MODULE
ZONE2 UNMUTE
PRE OUT
INPUT 6
INPUT 7
INPUT 8
INPUT 9
MODULE
MIC VOX
PHANTOM

OUTPUT

TRANSFORMER

b50side

Push to Talk Key

SHIELD

Lo Z

HOT

COMMON

SECOND ZONE

RVC10W MASTER

REMOTE

VOLUME CONTROL

10 K POT

ZONE ONE MUSIC
SOURCE CONNECTED
TO PHONE MUSIC
ON HOLD INPUT

SECOND ZONE MICROPHONE.
MIC VOX

Z2 MV11

IS TURNED ON

WHEN MICROPHONE IS ACTIVATED
MUSIC WILL BE MUTED.

OP

AMP

RVC

LOGIC

POWER

AMP

POWER

AMP

OP

AMP

MOH

Input

600

Ohm

Telephone System KSU

600 ohm MOH System

Telephone

Power Output

5 Watt

+

-

8 Ohm

Zone 1

MIC

INPUT

15 WATT

OUTPUT

5 WATT

OUTPUT

MOH

RVC+ MASTER

SECOND ZONE 70 VOLT
SPEAKERS

ZONE ONE SPEAKER
OUTPUT MAY BE USED
TO COVER AN AREA
(LOBBY OR ENTRANCE)
WITH MUSIC ONLY
WITHOUT PAGING
INTERRUPTION

1.25W

1.25W

1.25W

1.25W

8

OHM

8

OHM

8

OHM

8

OHM

ZONE ONE FOUR
SPEAKER OPTION
DIAGRAM

Advertising
This manual is related to the following products: