ESCAPE OF GAS

Should a gas leak be suspected, contact your gas
supplier without delay.

GAS EMERGENCY NUMBER: 0800111999

Do NOT search for gas leaks with a naked fl ame.
WARNING: This appliance must be earthed.


1 INTRODUCTION

1.1
Please carefully read the information given in this booklet
to help you gain maximum control from your appliance
with minimum trouble and cost.

1.2 Your White Boiler Company Condensing Low Nox
combination boiler has been designed to supply your
Central Heating and Domestic Hot Water directly from
one unit. When Central Heating is operating, the
circulation will be interrupted when Domestic Hot Water
is being drawn off.
This will normally not affect the level of Heating.


PLEASE NOTE:

Due to the high effi ciency and resulting low fl ue gas
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the fl ue outlet
terminal, this is quite normal. It will be particularly evident
during periods of low outdoor temperature or when the
boiler is working at its optimum performance
(Plume Management kit is available on request).

IMPORTANT:

in the event of the exhaust fl ue gases exceeding the
overheat temperature setting, the boiler operation will be
stopped to prevent damage to the appliance.

1.3 CLEARANCES AROUND THE BOILER

Above 125 mm
Below 75 mm min. recommended 150 mm
Front 450 mm
Sides 5 mm min. recommended 50 mm right

side

25 mm in front when installed in a cupboard.

1.3.1 Minimum clearences are required for safety and
maintenance. Do NOT obstruct any purpose made
ventilation opening if boiler has been fi tted in a
compartment.
Never hang clothes, etc, over the appliance.

1.4 USER CONTROLS (Fig.1)

1.4.1 This appliance is designed to operate with the
minimum of attention by the User. All the controls
are to be found on the control panel.

1.5 OPERATING SAFETY CHECKS TO PROTECT
YOUR APPLIANCE

1.5.1 Before lighting the appliance check Central Heating
system pressure (pressure gauge fi g.1) is not less
than 1 bar. If it is below, it will be necessary to
repressurise the system, a the appliance requires
system pressure to be maintened between 1 and
1.5 bar to allow the boiler to operate. A fi lling device
(fi lling loop) will have been fi tted on the system. This
will be usually on pipework near to the boiler. If you
are unsure of its position, or cannot identify it,
consult the installer who fi tted the boiler.
The fi lling loop consists of two taps and a separate
silver coulured braided fl exible pipe with connection
fi ttings. Only when repressuring should the braided
fl exible pipe be connected between the two taps.
Ensure that the nuts or the pipe ends are tightened
onto the taps.
Fully open one of the taps fi rst and then while
watching the pressure gauge, carefully open the
second tap. When the needle on the gauge is
indicating above 1 with a maximum of 1.5 bar turn
both taps off.
Disconnect the fl exible pipe from the taps (a small
amount of water may be present) and remove it.
Keep the pipe in a safe place for future use.

1.5.2 In the event of an error display at in the appliance
there will be a sequence code (Table of sequence
codes page 4) displayed on the Digital Display of
the control panel (fi g. 1).
By pressing the “RESET“ button (fi g. 1) for 1 to 3
seconds it is possible to relight the boiler.

USER’S GUIDE

WH 100 / 130 (T)

(with or without built in timer)

THE WHITE BOILER COMPANY

HIGH EFFICIENT CONDENSING COMBINATION BOILER

It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and to the current Gas Safety
(Installation and Use) Regulations B.S.5440:2-(2000).

All registered installers carry a Gas Safe Register ID card
and have a registration number. Both should be recorded in
your boiler Log book. You can check your installer on the
Gas Safe Register.