Technical data – REMKO ML 260 User Manual

Page 12

Advertising
background image

12

ML 260

ML 350

ML 520

ML 680

Nominal cooling capacity*

kW

2.59

3.50

5.27

6.80

Energy efficiency class cooling

C

C

D

D

Energy efficiency ratio

EER

2.82 2.82 2.61 2.61

Operational area (

size of room

), approx.

80

110

160

230

Refrigerant R

407C

Injection pipe connection

Inches

(mm)

1/4 (6.35)

3/8 (9.52)

Suction pipe connection

Inches

(mm)

3/8 (9.52)

1/2 (12.7)

5/8 (16.0)

Refrigerant pipe, length max.

m

10

15

Refrigerant pipe, height max.

5

8

Refrigerant, base quantity

g

680

1050

1700

1730

Refrigerant, additional amount > 5 m

g/m

15

20

30

35

Power supply

V/Ph/Hz

230 / 1~ / 50

Nominal power consumption cooling *

kW

0.92

1.24

2.02

2.61

Nominal current consumption cooling* A

4.35

5.55

10.58

13.45

Respective indoor unit

ML 260-IT

ML 350-IT

ML 520-IT

ML 680-IT

Operating range

°C

+16 to +32

Circulating air volume per speed

m³/h 270/320/400

330/410/500

500/610/750

600/730/900

Protection type

IP

X0

Sound pressure level per speed **

dB(A)

33 / 36 / 41

35 / 38 / 42

36 / 40 / 44

38 / 41 / 46

Dimensions

height

mm

268

286

326

width mm

788

886 1096

depth mm

180

180 215

Weight kg

8

9

15

15

Respective outdoor unit

ML 260-AT

ML 350-AT

ML 520-AT

ML 680-AT

Operating range

°C

+21 to +45 (with optional winter regulation -10 to +45)

Circulating air volume, max.

m³/h

1620

1740

2520

3600

Protection type

IP

X4

Sound pressure level, max. **

dB(A)

50

51

54

58

Dimensions

height

mm

543

548

605

730

width mm

645

700

805

860

depth mm

265

275

305

325

Weight kg

29

35

53

76

Serial number

700....

701....

702....

703....

Ref. number

1618260

1618350

1618520

1618680

Power consumption in 500 hours

kWh

460

620

1010

1305

Technical Data

*

Room temperature DB 27°C, WB 19°C; outside temperature DB 35°C, WB 24°C

** Distance

1m

Advertising
This manual is related to the following products: